Looking for how to relight gas water heater? There's a good chance you've turned on the hot tap only to find there's no hot water. One common reason is that the pilot light has gone out.
For many older gas hot water systems, relighting the pilot light is a straightforward job if it's done safely. However, not all gas water heaters have a pilot light, and if yours won't stay lit, it could point to a bigger issue that needs professional attention.
In this guide, we'll explain how to relight your gas hot water pilot light, what might have caused it to go out, and when it's time to call a plumber.
Before you start, it's worth checking what type of hot water system you have.
Older gas storage water heaters usually have a standing pilot light that stays on all the time. Many newer models, however, use electronic ignition, which means there's no pilot light to relight manually.
If you're not sure which type you have, check the instruction label on the unit or refer to the manufacturer's manual.
A pilot light can go out for several reasons, and it doesn't always mean your hot water system needs replacing.
Some common causes include:
If the pilot has only gone out once, relighting it may be all that's needed. If it keeps happening, it's worth having the system inspected.

While the exact steps can vary between manufacturers, most gas storage hot water systems follow a similar process.
Locate the gas control knob and turn it to the Off position.
Wait at least five minutes before continuing. This allows any remaining gas to disperse safely.
Open the small access panel near the bottom of the hot water unit. You should be able to see the pilot burner and ignition area.
Rotate the gas control knob to the Pilot setting.
Depending on your model, you may need to press and hold the knob to allow gas to flow to the pilot.
If your system has a built-in igniter, press the ignition button until the pilot lights.
Older systems without an igniter may require a long-reach lighter or match. Always follow the manufacturer's instructions for your specific model.
Keep holding the control knob down for around 30 to 60 seconds after the pilot flame appears. This gives the safety device time to detect the flame before you release the knob.
Once the pilot stays lit, turn the gas control from Pilot to On.
The main burner should ignite when the hot water system calls for heat.
Replace the access panel once everything is operating normally.
If the flame goes out as soon as you release the control knob, repeatedly trying to relight it probably won't solve the problem.
Some common reasons include:
The thermocouple is a safety device that detects the pilot flame. If it's worn or damaged, it may shut off the gas supply even when the flame is lit.
Dust, rust or spider webs can partially block the pilot burner, making it difficult for the flame to stay stable.
Low gas pressure or a problem with the gas supply can prevent the pilot from operating properly.
Like any mechanical component, the gas control valve can wear out over time and may need replacing.
Working around gas appliances always requires care.
Before attempting to relight the pilot:
If you suspect a gas leak, leave the area and contact a licensed gas fitter as soon as possible.

Relighting the pilot light is only suitable if the system is otherwise operating normally.
It's best to arrange a professional inspection if:
A licensed plumber can identify the cause safely and recommend the most appropriate repair.
This can be caused by a faulty thermocouple, a dirty pilot burner, gas supply issues or worn components inside the unit.
Many older gas storage systems allow homeowners to relight the pilot by following the manufacturer's instructions. If you're unsure or notice anything unusual, it's safest to contact a licensed plumber.
If the pilot stays lit but the water doesn't heat up, there may be another fault with the burner, thermostat or gas supply.
No. If the pilot repeatedly goes out, there's likely an underlying issue that should be inspected by a licensed professional.
No. Many newer gas hot water systems use electronic ignition instead of a standing pilot light.
Knowing how to relight your gas hot water pilot light can help restore your hot water if the pilot has simply gone out. In many cases, it's a quick fix, but if the flame won't stay lit or the system continues to play up, it's a sign that something else may be wrong.
At Vort Plumbing, we repair and service gas hot water systems across Adelaide. Whether your pilot light won't relight, your hot water has stopped working or you need help diagnosing a fault, our experienced plumbers are ready to get your hot water running again.
Contact our team today to book an inspection or repair.